Hygiene Plan for H&H Dental
The H&H Dental clinic uses the state-of-the-art products, appliances and methods for disinfection, cleaning and sterilization according to the most up-to-date standards.
The H&H Dental sterilization protocol
WHAT? | HOW? | WITH? | WHEN? | WHO? |
![]() Dentistry instruments used for examination and treatment: Mirrors, retractors, forceps, probes, impression trays etc. Surgical instruments: Heat-stable OP material |
By chemical solutions | Specific disinfectant | Immediately after treatment | The person responsible for sterilization |
Sterilization | Autoclave | – | dental assistant | |
Thermal disinfection: remove wire trays with instruments from disposal container (do not unpack instruments) |
Thermal disinfection | – | dental assistant | |
![]() Rotary instruments: Burs, fraser and polishing rubbers |
Disinfection in three phases:-chemical solution-ultrasonic cleaning-sterilization | – | Immediately after treatment | dental assistant |
![]() Handpieces, ultrasonic scalers
|
Desinfectant spray, Sterilization!!! | – | Immediately after treatment;At a daily rate. | dental assistant |
![]() Floors, surgeries, waiting rooms
|
Clean and disinfect using scrub-and-wash process, fully wet surfaces |
– | Daily, after finishing work | Cleaning personnel |
![]() Main dental units, trolleys, work surfaces
|
Spray disinfection, wipe-and-wash | – | In the working zone each morning and after every treatment | Dental assistant |
![]() Objects and surfaces which cannot be thermally
disinfected |
Spray disinfection, wipe-and-wash | – | -At the start and at the end of working day-After treatments, if necessary | Dental assistant |
![]() Hands: -Soiled side -Clean side |
Rub dry hands with 3 ml disinfectant for 30 sec., wash hands if contaminated, dry;Care for hands regularly | Hand disinfectant | Before work, after toilet-After contamination, before breaks-After end of work, before work, after breaks | Dentist, Dental assistant |
![]() Suction unit
|
1. Drain through with a mixture of air and water | ![]() Hygosuc system, Dürr
|
After every treatment, especially if blood was present | Dental assistant |
2. Disinfection, cleaning: slowly exhaust a mixture of air and a desinfectant solution | ![]() Hygosuc system, Dürr
|
At the end of work or whenever necessary | Dental assistant | |
3. Filter change: without touching the contaminated parts of the filter, using disposable gloves |
![]() |
Weekly or whenever necessary | Dental assistant | |
![]() Air conditioner
|
As described in the manual | As described in the manual | If necessary | Maintenance personnel |
![]() Containers
|
Emptying into the safe-containers | Plastic containers with safety lids | If necessary | Dental assistant |
Protecting the patients and personnel from cross-infections by:
SINGLE USE (DISPOSABLE)
- cups, towels, napkins, headrest
- protectors, suction – tubes
- examination gloves, protection glasses, face-masks
To protect our environment from infection and pollution, we exclusively use dental units equipped with an amalgam separator. All dangerous, infected waste is collected, stored and transported to the place of annihilation in separate, safe and unbreakable containers.